CJKHM - TOPCOATS-BRUSH GOODS, 7767

  • MSDS: CJKHM
  • Manufacturer: RUST OLEUM CORP
  • Product Name: TOPCOATS-BRUSH GOODS, 7767
  • National Stock Number: -
Product Identification

Product ID:TOPCOATS-BRUSH GOODS, 7767
MSDS Date:12/09/1994
FSC:NIIN:Submitter:N EN
Status Code:A
MSDS Number: CJKHM

Responsible Party
RUST-OLEUM CORPORATION
11 HAWTHORN PARKWAY
VERNON HILLS, IL 60061
US

Emergency Phone: 708-367-7700

Info Phone: 708-367-7700

Cage: 08882

Contractor
RUST-OLEUM CORP
VERNON HILLS, IL 60061-1583 US

Telephone: 847-367-7700

Cage: 08882

Ingredients

2.0 MM HG @ 20C.

CAS: 8052-41-3

RTECS: WJ8925000

OSHA PEL 2900 MG/M3;500 PPM

ACGIH TLV: 525 MG/M3;100 PPM

Hazards

Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: INHALATION: HARMFUL IF INHALED.
MAY AFFECT BRAIN OR NERVOUS SYSTEM, CAUSING DIZZINESS, HEADACHE OR
NAUSEA. REPEATED OVEREXPOSURES MAY PROGRESSIVELY LEAD TO STAGGERING
GAIT, CONFUSION, UNCONSCIO USNESS OR COMA. CAUSES NOSE AND THROAT
IRRITATION. SKIN OR EYE CONTACT: CAUSES SKIN AND EYE IRRITATION
WHICH CAN LEAD TO DERMATITIS WITH REPEATED OVEREXPOSURES.
INGESTION: MAY CAUSE GASTROINTESTINAL I RRITATION, NAUSEA, VOMITING
AND DIARRHEA. CHRONIC: REPORTS HAVE ASSOCIATED REPEATED AND
PROLONGED OCCUPATIONAL OVEREXPOSURE TO SOLVENTS WITH PERMANENT
BRAIN AND NERVOUS SYSTEM DAMAGE.
Effects of Overexposure:SEE HEALTH HAZARDS.

First Aid

First Aid:INHALATION: REMOVE FROM EXPOSURE, RESTORE BREATHING & NOTIFY
MD. EYES: FLUSH IMMEDIATELY WITH LARGE AMOUNTS OF WATER FOR AT
LEAST 15 MINUTES. NOTIFY MD. SKIN: WASH AFFECTED AREA WITH SOAP &
WATER, REM OVE CONTAMINATED CLOTHING & WASH BEFORE REUSE.
INGESTION: DO NOT INDUCE VOMITING. KEEP PERSON WARM, QUIET & GET
MEDICAL ATTENTION. ASPIRATION OF MATERIAL INTO LUNGS CAN CAUSE
CHEMICAL PNEUMONITIS WHIC H CAN BE FATAL.

Fire Fighting

Flash Point Method:SCC
Flash Point:>38.9C, 102.F
102-105F
Lower Limits:SEE ING
Extinguishing Media:NFPA CLASS B EXTINGUISHERS (CARBON DIOXIDE, DRY
CHEMICAL OR FOAM).
Fire Fighting Procedures:USE NIOSH APPROVED SCBA AND FULL PROTECTIVE
EQUIPMENT . WATER SPRAY MAY BE INEFFECTIVE. WATER MAY BE USED TO
COOL CLOSED CONTAINERS TO PREVENT PRESSURE BUILD-UP & POSSIBLE
AUTOIGNITION OR EXPLOS ION. IF WATER IS USED, FOG NOZZLES ARE
PREFERABLE.
Unusual Fire/Explosion Hazard:FLAMMABILITY CLASSIFICATION: OSHA CLASS
II. COMBUSTIBLE LIQUID. KEEP CONTAINERS TIGHTLY CLOSED. ISOLATE
FROM HEAT, ELECTRICAL EQUIPMENT, SPARKS & OPEN FLAME. CLOSED
CONTAINERS MAY EXPLODE WHEN EXPOSED TO EXTREME HEAT. DO NOT APPLY
TO HOT SURFACES.

Accidental Release

Spill Release Procedures:REMOVE ALL SOURCES OF IGNITION. VENTILATE AREA
& REMOVE W/INERT ABSORBENT & NON-SPARKING TOOLS.

Handling

Handling and Storage Precautions:DO NOT STORE ABOVE 120F. STORE LARGE
QUANTITIES IN BUILDINGS DESIGNED & PROTECTED FOR STORAGE OF NFPA
CLASS II COMBUSTIBLE LIQUID. CONTAINERS SHOULD BE GROUNDED WHEN
POURING. EMPTY CONTAINERS MAY BE H AZARDOUS.

Exposure Controls

Respiratory Protection:USE NIOSH APPROVED CHEMICAL CARTRIDGE RESPIRATOR
(TC23C) TO REMOVE SOLID AIRBORNE PARTICLES OF OVERSPRAY & ORGANIC
VAPORS DURING SPRAY APPLICATION. IN CONFINED AREAS: USE NIOSH
APPROVED SUPPLIED-AIR R ESPIRATORS OR HOODS (TC19C).
Ventilation:PROVIDE GENERAL DILUTION OR LOCAL EXHAUST VENTILATION IN
VOLUME & PATTERN TO KEEP TLV OF HAZARDOUS INGREDIENTS BELOW
ACCEPTABLE LIMITS.
Protective Gloves:IMPERVIOUS GLOVES.
Eye Protection:ANSI APPROVED CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:EYE WASH & DELUGE SHOWER MEETING ANSI DESIGN
CRITERIA . USE IMPERVIOUS CLOTHING TO PREVENT SKIN CONTACT.
Supplemental Safety and Health

Chemical Properties

Boiling Pt:>152.8C, 307.F
B.P. Text:307-389F (153-198C)
Vapor Pres:SEE INGREDIENT
Vapor Density:HVR/AIR
Spec Gravity:0.99-1.38
Evaporation Rate & Reference:SLOWER (ETHER=1)
Percent Volatiles by Volume:42-65

Stability

Stability Indicator/Materials to Avoid:YES
INCOMPATIBLE WITH STRONG OXIDIZING AGENTS.
Hazardous Decomposition Products:BY OPEN FLAME - CARBON MONOXIDE &
CARBON DIOXIDE.
Conditions to Avoid Polymerization:WILL NOT OCCUR.

Disposal

Waste Disposal Methods:DISPOSE OF ACCORDING TO LOCAL, STATE & FEDERAL
REGULATIONS. DO NOT INCINERATE CLOSED CONTAINERS.

Toxicology

Toxicological Information:NO INFORMATION IS AVAILABLE ON THE LC50 OR
LD50 OF THE PRODUCT AS A MIXTURE. HOWEVER, OPERATIONS SUCH AS
BURNING, WELDING, GRINDING,ETC MAY FORM OXIDE PRODUCTS OF THE
LISTED HAZARDOUS INGREDIENTS FOR WHICH SOME TOXICOLOGICAL
INFORMATION IS AVAILABLE. BYPRODUCTS: ALUMINUM OXIDE (AL2O3) LD50=
NOT ESTABLISHED, LC50= NONE ESTABLISHED. TITANIUM DIOXIDE (TIO2)
LD50= NONE ESTABLISHED, LC50= NONE ESTABLIS HED. VANADIUM PENTOXIDE
(V2O5) LD50= 10 MG/KG (ORAL RAT), LC50= NONE ESTABLISHED.

Other Information

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.

Ecology

Ecological:NONE PROVIDED BY MSDS

Transport

Transport Information:DOT CLASSIFICATION: FLAMMABLE LIQUID 3 PG III.

Regulatory

State Regulatory Information:CALIFORNIA PROPOSITION 65 STATEMENT: THESE
PRODUCTS ARE NOT KNOWN TO CONTAIN ANY CHEMICALS
KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER,
BIRTH DEFECTS OR OTHER REPRODUCTIVE HARM.